6.
Return remote control throttle lever to idle posi-
tion and check to ensure that throttle plates are
completely closed.
7. Reinstall flame arrestor and tighten locknuts se-
curely. Position crankcase vent hose against
flame arrestor as shown.
g
a
e
71764
a - Crankcase Vent Hose
a
f
72791
IMPORTANT: Do not attach any accessory
ground (–) wires to transom plate ground point.
Accessory ground wires should only be attached
to ground stud on engine.
d
b
8.
Connect any grounding wires or accessories that
may have been disconnected.
c
71761
9.
Models with MerCathode: Connect wires to
MerCathode controller assembly as shown.
Apply a thin coat of Quicksilver Liquid Neoprene
to all connections.
a - Cable End Guide
b - Cable Barrel
c - Bolt
d - Locknut
e - Throttle Lever
f - Flat Washer and Lockwasher
g - Throttle Plates
c
b
a
b
c
d
d
22232
a - ORANGE Wire - From Electrode On Transom Assembly
b - RED/PURPLE Wire - Connect (Other End) to Positive
(+)
c - BLACK Wire - From Engine Harness
Battery Terminal
W.O.T.
a
d - BROWN Wire - From Electrode on Transom Assembly
IDLE
72794
a - Throttle Lever
b - Positive Stop Screw
c - Throttle Stop Lever
d - Throttle Stop Screw
Index
2A-10 - MCM MODELS - BRAVO AND BLACKHAWK DRIVES
90-823224--2 796
Product Specification
Categories | Mercury MerCruiser Manuals |
---|---|
Tags | Mercury MerCruiser 454 CID, Mercury MerCruiser 502 CID |
Model Year | 1993, 1994, 1995, 1996, 1997 |
Download File |
|
Document File Type | |
Copyright | Attribution Non-commercial |
Hugely helpful service manual! Perfect. Thank you!
Manuals are all Important for Technician
This book is invaluable if you do your own repairs. Great book.
Could not find a copy until a search brought me here.
Excellent print.
Thank you