4.
Lower drive unit to full IN position.
!
CAUTION
Watch temperature gauge on dash to ensure that
engine does not overheat.
!
CAUTION
Do not run engine above 1500 RPM when flush-
ing. Suction created by seawater pickup pump
may collapse flushing hose, causing engine to
overheat.
3.
4.
5.
Partially open water tap (approximately 1/2 maxi-
mum capacity). DO NOT use full water pressure.
Place remote control in neutral, idle speed posi-
tion, and start engine.
Operate engine at idle speed in neutral for 10
minutes, or until discharge water is clear, then
stop engine.
!
CAUTION
Watch temperature gauge on dash to ensure that
engine does not overheat.
6.
Shut off water tap. Remove garden hose and
flushing attachment.
5.
Partially open water tap (approximately 1/2 maxi-
mum capacity). DO NOT use full water pressure.
BOAT IN WATER
1.
2.
Raise drive unit to full UP position.
6. Place remote control in neutral, idle speed posi-
tion, and start engine.
Install flushing attachment over water pickup
holes in gear housing as shown.
7. Operate engine at idle speed in neutral for 10
minutes, then stop engine.
3.
Attach a garden hose between the flushing at-
tachment and a water tap.
8. Shut off water tap.
9.
Raise drive unit to full UP position.
10.
Remove garden hose and flushing attachment.
a
b
72693
a - Flushing Attachment
b - Hose
Index
1B-14 - MAINTENANCE
90-823224--2 796
Product Specification
Categories | Mercury MerCruiser Manuals |
---|---|
Tags | Mercury MerCruiser 454 CID, Mercury MerCruiser 502 CID |
Model Year | 1993, 1994, 1995, 1996, 1997 |
Download File |
|
Document File Type | |
Copyright | Attribution Non-commercial |
Hugely helpful service manual! Perfect. Thank you!
Manuals are all Important for Technician
This book is invaluable if you do your own repairs. Great book.
Could not find a copy until a search brought me here.
Excellent print.
Thank you