SERVICE MANUAL NUMBER 24
SEAWATER COOLED MODELS
Quicksilver Sea Strainer
NOTICE
Refer to manufacturer’s instructions for information on other than Quicksilver Sea
Strainer.
Removal
CAUTION
If boat is in water while working on seawater strainer, close seacock, if so equipped.
If boat is not equipped with a seacock, remove and plug seawater inlet hose to pre-
vent a siphoning action that may occur, allowing seawater to flow from the drain
holes or removed hoses and enter boat.
1.
Follow “a” or “b” instructions:
a. Models Equipped with Seacock:
(1.)
(2.)
Close seacock (seawater inlet valve).
Disconnect seawater inlet hose from seawater strainer.
b. Models without Seacock:
(1.)
Disconnect seawater inlet hose from seawater strainer inlet and plug seawater
inlet hose.
a
b
d
c
70062
a - Seawater Inlet Hose
b - Seawater Strainer
c - Seawater Strainer Inlet
d - Plug
2.
Remove outlet hose. Drain into a suitable container.
a
b
72643
a - Seawater Inlet Hose
b - Seawater Strainer
3.
Remove mounting bolts. Remove strainer.
Index
90-861327--1
OCTOBER 1999
Page 6A-7
Product Specification
Categories | Mercury MerCruiser Manuals |
---|---|
Tags | Mercury MerCruiser 305 CID, Mercury MerCruiser 350 CID |
Model Year | 1998, 1999, 2000, 2001 |
Download File |
|
Document File Type | |
Copyright | Attribution Non-commercial |
Great performance engine.