SERVICE MANUAL NUMBER 24
STARTING SYSTEM
Testing
CAUTION
Test battery in well ventilated area as gases given off by battery are hazardous.
A strong battery must be maintained. If battery shows less than 9.5 volts when under starting
load, (at 80° F or 27° C) it should be recharged. Check with DC voltmeter.
9.5
b
a
76498
a - Voltmeter
b - Battery
Place battery under heavy load (as during engine cranking or with a variable resistor tester)
and test cell voltage while under load.
Certain conditions must be met before testing.
•
•
•
•
Battery must be 60 to 100°F (16 to 38°C).
Electrolyte level must be correct in all cells.
Battery must be at least half charged.
No obvious defects.
1.
2.
3.
Check voltage per manufacturer’s specifications.
If readings are low, recharge and retest.
If readings remain low, battery should be replaced.