SERVICE MANUAL NUMBER 23
TROUBLE CODE DIAGNOSTICS - 7.4L MPI
Code 34 (3 of 3): Manifold Absolute Pressure (MAP) Sensor Circuit (Scan) -
Low Signal Voltage
STEP
ACTION
VALUE
YES
NO
PROCEED TO
Repair low or unsteady vacuum problem. Is
action complete?
6
7
–
–
–
Trouble code is intermittent. Locate and repair
intermittent faulty connections. Refer to “Diag-
nostic Aids”.
–
Locate and repair open or short to ground in
CKT 416E. If a problem is found, repair as
necessary. Was a problem found?
8
9
–
–
Step 11
Verify
Repair
Locate and repair open or short to ground in
CKT 432. If a problem is found, repair as nec-
essary. Was a problem found?
Step 11
Check for plugged or leaking sensor vacuum
fitting. If OK, replace faulty MAP sensor. Is
action complete?
10
11
–
–
–
–
Repair faulty ECM connections or replace
faulty ECM. Is action complete?