SERVICE MANUAL NUMBER 23
TROUBLE CODE DIAGNOSTICS - 7.4L MPI
Code 33 (2 of 3): Manifold Absolute Pressure (MAP) Sensor Circuit (Non-Scan)
High Signal Voltage (Continued)
Repair low or unsteady vacuum problem. Is
action complete?
Verify
Repair
5
6
–
–
–
–
Check for plugged or leaking sensor vacuum
fitting. If OK replace faulty MAP sensor. Is
action complete?
Verify
Repair
Locate and repair short to voltage in CKT 432.
If a problem is found, repair as necessary. Was
a problem found?
7
–
Step 9
Locate and repair open in CKT 814. If a prob-
lem is found, repair as necessary. Was a prob-
lem found?
Verify
Repair
8
9
–
–
Step 9
–
Repair faulty ECM connectors or replace faulty
ECM. Is action complete?