SERVICE MANUAL NUMBER 23
MIE MODELS - HURTH TRANSMISSION
c. Position crankcase ventilation hose against flame arrestor and rocker arm cover
fittings as shown.
a
71764
a - Crankcase Vent Hose
7.4L
MPI MODEL
1.
2.
Place remote control handle(s) in neutral idle position.
Remove port side engine cover.
IMPORTANT: Be sure that cable is routed to avoid sharp bends and/or contact with
moving parts. DO NOT fasten any items to throttle cable. Outer cable must be free to
move when cable is actuated.
3.
Remove flame arrestor.
a
c
b
75447
a - Flame Arrestor
b - Clamp
c - Engine Cover
4.
Install cable end guide on throttle lever, then push cable barrel end lightly toward throttle
lever end. (This will place a slight preload on shift cable to avoid slack in cable when
moving remote control lever.) Adjust barrel on throttle cable to align with hole in anchor
plate. Ensure hole in barrel positions cable as shown.
a
b
75455
a - Cable Barrel
b - Anchor Plate