SERVICE MANUAL NUMBER 23
MULTI-PORT FUEL INJECTION DESCRIPTIONS AND SYSTEM OPERATION
Electronic Control Module (ECM) and Sensors
General Description
The MerCruiser Electronic Fuel Injection system is equipped with a computer that provides
the operator with state-of-the-art control of fuel and spark delivery. Computers use voltage
to send and receive information.
Computers and Voltage Signals
Voltage is electrical pressure. Voltage does not flow in circuits. Instead, voltage causes cur-
rent. Current does the real work in electrical circuits. It is current, the flow of electrically
charged particles, that energizes solenoids, closes relays and lights lamps.
Besides causing currents in circuits, voltage can be used as a signal. Voltage signals can
send information by changing levels, changing waveform (shape), or changing the speed
at which the signal switches from one level to another. Computers use voltage signals to
communicate with one another. The different sections inside computers also use voltage
signals to communicate with each other.
There are two kinds of voltage signals, analog and digital. Both of these are used in
computer systems. It’s important to understand the difference between them and the
different ways they are used.
Analog Signals
An analog signal is continuously variable. This means that the signal can be any voltage
within a certain range. An analog signal usually gives information about a condition that
changes continuously over a certain range. For example, in a marine engine, temperature
is usually provided by an analog signal. There are two general types of sensors that produce
analog signals: the 3-wire and the 2-wire sensor.
THREE-WIRE SENSORS (MAP AND TP)
The following figure shows a schematic representation of a 3-wire sensor. All 3-wire sensors
have a reference voltage, a ground and a variable “wiper.” The lead coming off of the wiper
will be the signal to the Engine Control Module (ECM). As this wiper position changes, the
signal voltage returned to the computer also changes.
b
a
c
d
3-Wire
Sensor
a - Typical Sensor
b - ECM
c - Voltage Out
d - Signal Input
e - Sensor Ground
90-861326--1
MARCH 1999
Page 5B-15
Product Specification
Categories | Mercury MerCruiser Manuals |
---|---|
Tags | Mercury MerCruiser 454 CID, Mercury MerCruiser 502 CID |
Model Year | 1998, 1999, 2000, 2001 |
Download File |
|
Document File Type | |
Copyright | Attribution Non-commercial |
Just need the manual. Wrote review. Can't technically review what I haven't seen yet...