TROUBLE CODE DIAGNOSTICS - 7.4L MPI
SERVICE MANUAL NUMBER 23
Code 33 (2 of 3): Manifold Absolute Pressure (MAP) Sensor Circuit (Scan)
High Signal Voltage
STEP
ACTION
VALUE
YES
NO
PROCEED TO
Repair low or unsteady vacuum problem. Is
action complete?
6
7
–
–
–
Trouble code is intermittent. Locate and repair
intermittent faulty connections. Refer to “Diag-
nostic Aids”.
–
Locate and repair short to voltage in CKT 432.
If a problem is found, repair as necessary. Was
a problem found?
8
9
–
–
Step 11
Verify
Repair
Locate and repair open in CKT 814. If a prob-
lem is found, repair as necessary. Was a prob-
lem found?
Step 11
Check for plugged or leaking sensor vacuum
fitting. If OK, replace faulty MAP sensor. Is
action complete?
10
11
–
–
–
–
Repair faulty ECM connections or replace
faulty ECM. Is action complete?