CORROSION PROTECTION - ALL MODELS
SERVICE MANUAL NUMBER 28
CAUTION
DO NOT paint sacrificial anodes or MerCathode System electrode assembly, as this
will render them ineffective as galvanic corrosion inhibitors.
8.
Position and secure electrode assembly to gimbal housing using two 1-3/8 in. (35 mm)
long screws, flat washers and lockwashers. Torque to 25 lb-in. (2.8 Nm). Do NOT
overtighten.
e
a
c
d
b
70771
a - Electrode Assembly
b - Screw (2)
c - Flat Washer (2)
d - Lock Washer (2)
e - Hydraulic Connector Block
Connect Electrical Leads to Controller Assembly
NOTE: If black (ground) wire is not available at terminal block or from wire harness, install
a separate lead between controller negative (–) terminal and negative (–) battery cable at-
taching point on engine.
1.
Securely connect electrical leads to controller assembly. (See Wiring Diagrams,
following.)
2.
Apply a thin coat of Quicksilver Liquid Neoprene (92-25711) to ALL electrical
connections.