OILDYNE TRIM PUMP
SERVICE MANUAL NUMBER 28
4.
Zero Ohms Reading (Full Continuity)-Solenoid is OK.
High Ohms Reading (No Continuity)-Replace solenoid.
NOTE: See the wiring diagram on page 5A-51.
110
Amp Fuse Test (Pump in Boat)
WARNING
DO NOT perform this test near flammables (or explosives) as a spark may occur
when making connections.
1.
Check for voltage at battery power terminal using a volt meter. Voltage MUST BE indi-
cated before proceeding with the next check.
c
a
d
b
22495
a - Volt Meter Negative (–) Lead
b - Volt Meter Positive (+) Lead
c - Fuse (RED in Color)
d - Battery Power Terminal
2.
Check for voltage at protected terminal of110 Amp fuse using a volt meter.
a
c
b
d
22493
a - Volt Meter Negative (–) Lead
b - Volt Meter Positive (+) Lead
c - Fuse (RED in Color)
d - Protected Terminal Of 110 Amp Fuse
3.
Voltage Indicated: Fuse OK.
Voltage Not Indicated: Replace the fuse.