OILDYNE TRIM PUMP
SERVICE MANUAL NUMBER 28
3.
Connect the ohmmeter between the field brush lead and the GREEN/WHITE lead.
a
b
22642
a - Ohmmeter Lead - Connected to Brush Lead
b - Ohmmeter Lead - Connected to GREEN/WHITE Lead
4.
Zero ohms indicated (full continuity) - Field OK.
Zero ohms not indicated (no continuity) - Replace field assembly.
Test for Short in Field
1.
Connect the ohmmeter between the field brush lead and the field frame.
a
b
22643
a - Field Frame
b - Field Brush Lead
2.
Zero ohms indicated (full continuity) - Short indicated (replace field assembly).
Zero ohms not indicated (no continuity) - Field OK.