SERVICE MANUAL NUMBER 28
OILDYNE TRIM PUMP
3.
Run the pump OUT/UP until the gauge reading reaches 2200-2600 psi (15173-17932
kPa). Stop pumping OUT/UP. The pressure should not fall below 1900 psi (13104 kPa).
If gauge reading is 1900 psi (13104 kPa) or above, UP pressure test completed.
If gauge reading is below 1900 psi (13104 kPa) perform the following:
Check for External Oil Leaks,
Correct and Retest
Up Pressure
Test Completed
Reading OK
Reading OK
Reading OK
Reading NOT OK
Replace Thermal Relief
Valve (4) and Retest
Up Pressure
Test Completed
Reading NOT OK
Install Trim Pump Rebuild
Kit and Retest
Up Pressure
Test Completed
Reading NOT OK
Replace Adaptor (2)