13.
Once shift cable adjustment is correct, secure shift cable(s) with hardware as shown,
referring to appropriate configuration following:
NOTE: To change cable approach direction on single or dual station installations, only the
spacer/bushings have to be switched to the opposite stud. The studs are identical.
IMPORTANT: Tighten locknut until it contacts and then loosen 1/2 turn.
d
e
g
c
b
h
f
a
71210
72955
b
Typical Single Cable - Forward Approach
a - Cable End Guide
b - Locknut and Washer
c - Spacer (Fits Over Bushings)
d - Bushing
e - Cable Barrel
f - Spacers (Fits Over Stud)
g - Cable Barrel Stud
h - Cable End Guide Stud
f
g
a
b
e
h
d
50229
c
72957
b
Typical Single Cable - Rear Approach
a - Cable End Guide
b - Locknut And Washer
c - Spacer (Fits Over Bushings)
d - Bushing
e - Cable Barrel
f - Cable Barrel Stud
g - Cable End Guide Stud