CHARGING SYSTEM
SERVICE MANUAL NUMBER 30
5.
If the voltmeter reading at the battery posts is below 13.5 volts, connect the voltmeter
positive (+) lead to the alternator output terminal. Connect the voltmeter negative (–)
lead to the ground terminal on the alternator. Repeat step 4.
c
X.X
a
–
+
76498
b
76533
Typical
a - Output Terminal
b - Ground Terminal
c - Voltmeter
6.
7.
If voltmeter reading is now within specifications, there is too much resistance between
the alternator and the battery.
If the reading is below 12.5 volts, the alternator may not be charging. Check all wiring
leading to the alternator.