SERVICE MANUAL NUMBER 30
CHARGING SYSTEM
Charging System Resistance
1.
2.
3.
4.
Disconnect both coil pack wiring harness connections so that the engine does not start.
Crank engine over for 15 seconds to discharge the battery slightly.
Reconnect both coil pack wiring harness connections and turn off all accessories.
Connect the voltmeter positive (+) lead to the alternator output terminal. Connect the
voltmeter negative (–) lead to the battery positive (+) post.
NOTE: Connect voltmeter leads to the battery post, NOT the battery cable end.
c
d
X.X
+
–
a
–
+
76498
b
76533
Typical
a - Output Terminal
b - Ground Terminal
c - Voltmeter
d - Battery
5.
Start engine and run at 1300-1500 rpm. Read voltmeter. A reading of more than 0.5 volts
shows excessive resistance in wiring.