STARTING SYSTEM
SERVICE MANUAL NUMBER 30
Installation
IMPORTANT: Install special mounting shim (if equipped) between starter motor and
engine block.
1.
2.
Place starter motor in position and install mounting bolts. Torque bolts to 30 lb-ft (41 Nm).
Connect YELLOW/RED wire to the upper solenoid terminal. Connect ORANGE wire,
RED wire, and battery cable to the lower solenoid terminal. Tighten fasteners securely.
Coat terminals with Quicksilver Liquid Neoprene. Install battery cable boot, if equipped.
a
b
77588
a - Upper Solenoid Terminal
b - Lower Solenoid Terminal
3.
Connect battery cables to battery in the following order. Connect positive (+) cable to
positive (+) battery terminal and tighten cable clamp. Then connect negative (–) cable
to negative (–) terminal and tighten clamp.