c. As temperature rises, switch will close and ohmmeter will indicate continuity. Refer
to chart below for specifications.
48952
Switch
Opens
Closes
150-170°F (60-77°C)
190-200°F (88-93°C)
87-86080
Switch
Opens
Closes
175-195°F (79-91°C)
215-225°F (102-107°C)
a
b
72767
Switch Identification
a - 48952 Switch with Red Mylar Sleeve
b - 87-86080 Switch with Black Mylar Sleeve
4.
5.
Turn heat source off. Allow sand to cool. Note thermometer reading to ensure switch
“opens” up at specified temperature.
Replace switch if switch fails to either open or close within the specified temperatures.