Volvo Penta MD2010 MD2020 MD2030 MD2040 Workshop Manual

Fuel system
Repair   instructions
4.
Send the  pump to  an authorised  diesel  workshop�
for inspection  if the  workshop  does not  have spe-
cially trained  personnel  with the necessary  testing
equipment.
Observe  the greatest  possible  cleanliness  when  work-
ing  with the fuel system.
�MD2o10,   MD2020,  MD2030:  Nippondenso.
MD2040:  Bosch.
Injection pump
Dismantling  of the injection pump
NOTE! Repair  work  on the injection  pump which
may change  its setting  should  only be carried  out
by specially  trained  mechanics  which have  the
requisite  equipment  at their disposal.
Engine  warranties are  not longer  valid if the  seals
are broken  by unauthorised  personnel.
Fitting of the  injection pump
1.
Carefully  wash clean  the injection  pump,  pipes and
the engine  around the  pump.
Check  that the pump  is in good  condition,  and if so  re-
quired also  tested and  approved  before it is fitted.
2.
Close  the fuel cocks.  Remove  the delivery  pipe
complete.  Release  the fuel  hose from  the pump.
Note:  Do not remove  the protective  caps before  the
Fit protective  caps on all  connections.
pipes are  connected.
1.
Put the  injection pump  in the cylinder  block.
NOTE! Make  sure that  the shims  which were
placed  under the injection  pump  flange are  put
back in  place before  the pump  is�put  in the
block.
Note:  The correct  pump setting  is normally  ob-
tained  with this method.  If the  injection  pump, cam-
shaft or  cylinder block  have been  replaced the  set-
ting of the  pump must  be adjusted.  See next
section,  "Adjustment  of injection angle":
2.
Turn the  stop lever  clockwise  and connect  the
regulator  arm to the control  rod on  the pump. Fit  the
lock pin  (Fig. 87). Screw  tight the  pump.
3.
Connect  the fuel  hose and fuel  leak pipe  to the
pump. Fit  the delivery pipe.
4.
Bleed the  fuel system  and test run  the engine.
Fig. 87.  Dismantling  of the injection  pump
1.
Lock pin
2.  Shims
3.
Dismantle  the pump�s  attachment  screws  and nuts.
Turn the  stop lever  clockwise  and carefully  lift up
the pump  so that the  lock pin to the  regulator arm
becomes  accessible (Fig.  87).
Remove  the lock pin  and release  the regulator  arm.
NOTE! Take  care of  the shims under  the injec-
tion pump  flange when  the pump  is lifted off  the
cylinder  block.
54
Product Specification
CategoriesVolvo Penta Manuals
Tags, , ,
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 81 pages
Document File TypePDF
CopyrightAttribution Non-commercial
(4 votes, average: 4.25 out of 5)
Marine readers have rated Volvo Penta MD2010 MD2020 MD2030 MD2040 Workshop Manual 4.3 out of 5.0 based on 4 product reviews.
Submit your review (optional)
(will not be displayed)
* Required Field

Volvo Penta MD2010 MD2020 MD2030 MD2040 Workshop Manual SKU UPC Model
zljkn on Sep 15, 2018. YES

GOOD AND GOODER S=GOODEST. IS BESTER


Henning Hansen on Jul 16, 2018. Volvo penta md2030

jeg skal bruge manualen , til at samle min Volvo penta md 2030 igen.


X on Apr 28, 2018.

Ö, hur dka jag veta om det är bra innan jag set produkten.


rune on Oct 23, 2013.



One thought on “Volvo Penta MD2010 MD2020 MD2030 MD2040 Workshop Manual

  1. Pages 58 and 59 are missing from Volvo Penta MD2010 MD2020 MD2030 MD2040 Workshop Manual. I need only these pages at present!

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website