™
378
Vacuum
Generator
B. Head With Overboard Discharge
Sanx Filter
This option is available on the 378 Vista™ model. The
headoperatesthesameas the VacuFlush system above
but an additional line with a “Y” has been installed for
overboard discharge. The waste will be pumped into the
holding tank from the head. The macerator pump is in-
stalled after the “Y”. Refer to Figures J4 & J7.
P-Trap Air Vent
Waste
Deck Fill
Sanx Filter
Macerator
VacuFlush Holding Tank
Figure J5: VacuFlush Vacuum Generator
and Holding Tank
Single “Y”
To operate:
1.
To add water to the toilet before using, raise flush
lever until desired water level is reached. Gener-
ally, more water is required only when flushing sol-
ids. See Figure J6.
Seacock
2.
To flush toilet, press flush lever sharply down to the
flooruntilcontentsclearbowl. Asharppoppingnoise
is normal when the vacuum seal is broken and the
flushing action begins. Be sure to hold lever down
for 3 seconds. If flush lever is accidentally released
before waste clears bowl, do not attempt to flush
toilet again until vacuum pump stops running. A
small amount of water should remain in the bowl
after flushing.
Figure J7: Overboard Discharge Option
NOTICE
The macerator pump must be used to discharge
waste overboard. However, DO NOT use the
macerator pump to discharge waste at a pump-
ing station. If the hose is not air tight or connect-
ed properly, waste could spurt out or leak around
the deck fitting and into the boat.
3.
Do not dispose of sanitary napkins or other non-
dissolving items in toilet, such as facial tissue or
paper towels. These items can cause plugging of
the system. Refer to the Deodorants and Special
Tissue section in the manufacturer’s manual for
more information.
To operate the overboard discharge system:
1.
2.
3.
Thedischargevalveislocatedintheenginecompart-
ment. To open, turn the valve so that the handle is
parallel to the flow of the valve. The waste deck plate
cover must be tightened securely for the overboard
discharge system to operate.
1.
Water
Add
2.
Flush For
3 Seconds
3. Do Not
Turn ON the macerator pump switch which is located
in the head on the switch panel. Allow the pump to
run until the storage tank is empty. The sound of the
pump’s motor load and speed will change when the
tank becomes empty.
Lift
Press
Turn the switch off.
Figure J6: VacuFlush Operations
378
Vista™ Owner’s Manual
Section J
Page5
Categories | Four Winns Manuals, Four Winns Vista Manuals, Outboard Marine Corporation Manuals |
---|---|
Tags | Four Winns Vista 378 |
Model Year | 2002, 2003, 2004, 2005, 2006, 2007, 2008 |
Download File |
|
Document Type | Owner's Manual |
Language | English |
Product Brand | Boats and Cruisers, Four Winns. For support contact your dealer at http://www.fourwinns.com/locate-dealer.aspx |
Document File Type | |
Publisher | fourwinns.com |
Wikipedia's Page | Outboard Marine Corporation |
Copyright | Attribution Non-commercial |
(1 votes, average: 4 out of 4) Marine readers have rated 2002-2008 Four Winns Vista 378 Boat Owners Manual 4.0 out of 4.0 based on 1 product reviews.
great very informative. should not have to fill this out for a manule though