Using Your E-TEC Outboard
EMERGENCY STARTING
2) Remove fuse holder from flywheel cover.
If the starter fails, your engine can be started
using a 1/4 in (6 mm) cord about 4 ft. (1.2 m)
long.
WARNING
Move
the shift lever to NEUTRAL
before performing emergency starting
procedures. Failure to do so may result
in unexpected boat movement.
1
The engine cover is a machinery guard.
To prevent injury from moving engine
components, keep hands, clothes, and
hair clear of powerhead.
1.
Fuse
Prevent electric shock by keeping clear
of the ignition coils and spark plug
leads when the outboard is being
started or is running. Shock can cause
serious personal injury under certain
conditions.
3) Raise flywheel guard from the fittings by
pulling up on the front two fastening tabs.
DO NOT turn flywheel by hand. Use
starter cord only.
Be sure:
•
•
•
Key switch is OFF.
Engine is in normal operating position.
Shift lever is in NEUTRAL.
1
1)
Release port and starboard side engine
cover latches downward. Pull up on the tilt
handle to release the engine cover seal 1. Fastening tabs
and remove the engine cover.
4)
Holding the flywheel guard out of the way,
hook the knot of your emergency start cord
into the notch on the flywheel. Wind cord
clockwise in the flywheel ridge, making one
and a half full windings with the cord.
1
2
2
1.
2.
Engine cover latch
Tilt handle
3
1
1.
NEUTRAL
2.
3.
Knot
Rope in flywheel ridge
30
Categories | BRP Brand Manuals, Evinrude Brand Manuals, Evinrude E-TEC Manual, Evinrude Outboard Manual |
---|---|
Tags | Evinrude 75 hp, Evinrude 90 hp, Evinrude PL, Evinrude PX, Evinrude WEL, Evinrude WEX |
Model Year | 2009 |
Download File |
|
Document File Type | |
Copyright | Attribution Non-commercial |
(1 votes, average: 5 out of 5) Marine readers have rated 2009 Evinrude 75 90 hp E-TEC PL PX WEL WEX Outboard Motor Owners Manual 5.0 out of 5.0 based on 1 product reviews.
very good, had all info I needed