X ENGINE MONITORING
ENGINE MONITORING
The engine monitoring system warns you of For I-Command and other gauges, refer to the
conditions that could damage your outboard. gauge user’s guide for gauge displays, oper-
The monitoring system consists of a dash- ation, warnings, and monitoring instructions.
mounted gauge, a warning horn, sensors on
the engine and oil tank, and related wiring.
SYSTEM SELF-TEST
be
IMPORTANT:
Your
outboard
must
During engine start-up, pause with the key
switch in the ON position. The monitoring sys-
tem self-tests by sounding a half-second
beep. SystemCheck gauges self-test by turn-
ing the indicator lights on simultaneously,
then off in sequence.
equipped with an engine monitoring system
such as I-Command, SystemCheck, or equiv-
alent. Operating your outboard without an en-
gine monitor will void your warranty for
failures related to monitored functions.
The system is compatible with the Evinrude
Modular Wiring System (MWS) or can be con-
nected to an I-Command system, or other
NMEA 2000 compliant CANbus instruments.
IMPORTANT: If the self-test does not happen
as stated, see your Dealer.
ENGINE MONITOR WARNINGS
GAUGES
Gauges are available in several styles, such
as a digital I-Command gauge with LCD dis-
plays or a basic SystemCheck gauge.
Engine monitor system warnings activate the
horn for 10 seconds and the appropriate
gauge light for a minimum of 30 seconds, or
until alarm is acknowledged. If the failure is
momentary (for example, oil moving in the
tank), the engine monitor gauge light or dis-
play may remain ON for a full 30 seconds be-
fore going out. If the unsafe operating
condition continues, a light or display remains
ON until the key is turned OFF or the failure is
corrected.
The warning will reoccur at the next startup if
the problem is not corrected.
If the EMM senses a problem could cause
permanent engine damage, it will also limit
engine speed to 1200 RPM. This additional
protection feature is referred to as S.A.F.E.
(Speed Adjusting Failsafe Electronics). If the
engine was running faster than 1200 RPM
when the S.A.F.E. mode activated, it will
shake noticeably. Under certain operating
conditions the EMM will shut OFF the engine.
1
2
1.
2.
Typical I-Command Digital gauge
Typical SystemCheck gauge
Function
The EMM activates the warning horn and the
gauge displays as follows:
LOW OIL means that oil in the tank is at re-
serve level (about 1/4 full).
•
CAUTION
•
NO OIL indicates an oil delivery problem
such as an empty oil tank or damaged oil
system.
WATER TEMP or HOT indicates an engine
or EMM overheat condition.
CHECK ENGINE or FAULT is used to indi-
cate other fault conditions identified by the
EMM.
In the S.A.F.E. mode, the engine speed
is limited. Under certain conditions, the
engine’s limited speed may reduce
maneuverability of your boat.
•
•
If the S.A.F.E. mode is activated and
you are unable to correct the problem,
seek assistance and/or return to safe
harbor. Serious engine damage, engine
shutoff, and/or reduced maneuverabil-
ity may be imminent.
17
Categories | BRP Brand Manuals, Evinrude Brand Manuals, Evinrude E-TEC Manual, Evinrude Outboard Manual |
---|---|
Tags | Evinrude 75 hp, Evinrude 90 hp, Evinrude PL, Evinrude PX, Evinrude WEL, Evinrude WEX |
Model Year | 2009 |
Download File |
|
Document File Type | |
Copyright | Attribution Non-commercial |
(1 votes, average: 5 out of 5) Marine readers have rated 2009 Evinrude 75 90 hp E-TEC PL PX WEL WEX Outboard Motor Owners Manual 5.0 out of 5.0 based on 1 product reviews.
very good, had all info I needed