B.   Galvanic Corrosion
120
(220) volt AC electrical power can be danger-
Galvanic corrosion results from a potential electrical
difference existing between dissimilar metals im-
mersed in a conductive solution (e.g., salt or brackish
water). If these metals touch or are otherwise electri-
cally connected, this potential difference produces an
electron flow between them. The attack on the more
active metal is usually increased and the attack on the
less active metal is decreased, as compared to when
these metals are not touching.
ous. DO NOT attempt to service a system unless
youarefamiliarwith,andexperiencedin,perform-
ing such service.
H - 12  STRAY CURRENT CORROSION
A.   General
C.   Corrosion Prevention
Electrically induced underwater corrosion occasionally
affects boats and their related components. This is
referred to as “Stray Current Corro sion” and appears
as surface pitting or deterioration. Stray current
corrosion is the decomposition of chemical com-
pounds by electric current.
Anti-corrosion anodes are attached to the bottom
of the gimbal housing of your stern drive to prevent
corrosion to your electrical systems and underwater
parts. These anodes will be slowly eroded away by
galvanic action and require periodic inspection. Please
refer to the section on “Anti-Corrosion Anodes” in your
engine manufacturer’s manual for additional informa-
tion.
Stray current corrosion can be caused by surrounding
boats; an improperly wired battery/charger installation
or other boats that are in close proximity which have
electrical power leakages. Stern drive units are
especially vulnerable to stray current corrosion.
Periodically inspect the engine components to deter-
mine if corrosion damage exists. If stray current
corrosion damage is found, determine and correct the
cause of the stray current to prevent further damage.
Consult an experienced marine electrician or contact
your Four Winns dealer for assistance.
The use of some shore power battery chargers, while
the boat is in the water and the battery is connected to
the system, can cause stray current corrosion. Have
an experienced marine electrician review any battery
charger installation to ensure a stray current corrosion
problem will not develop. An improper battery connec-
tion is a common cause of stray current corrosion.
NOTICE
Use only UL Marine-ignition protected battery
charger(s) designed to meet US Coast Guard
regulations for external ignition protection.
Corrosion is usually more prevalent in polluted or salt
water than in fresh water. It is also more likely to occur
when dockage is in an area with steel piers, large
metal boats, or where shore power is in use.
Electrical Systems - Section H
Owner’s Manual Page 76
Product Specification
CategoriesFour Winns H-Series Manuals, Four Winns Manuals
Tags
Model Year2011
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 172 pages
Document TypeOwner's Manual
LanguageEnglish
Product BrandBoats and Cruisers, Four Winns. For support contact your dealer at http://www.fourwinns.com/locate-dealer.aspx
Document File TypePDF
Publisherfourwinns.com
Wikipedia's PageOutboard Marine Corporation
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website