X FUEL AND OIL
OIL REQUIREMENTS
If available, use the Evinrude Diagnostics
Software program oil priming function for a
minimum of 90 seconds.
If the diagnostics program is not available,
prime the oiling system by using the winteriza-
tion procedure. Refer to Long-Term Storage
(Winterization) on page 33.
outboard is run on heavy fuels. Evinrude/ Observe oil flow through the oil distribution
hoses.
Evinrude/Johnson
XD100 is the ONLY
outboard oil recommended for use with
Evinrude MFE outboards. Evinrude/Johnson
XD100 outboard oil MUST be used when
Johnson XD100 oil MUST be used when
operating in temperatures under 32°F (0°C).
Small bubbles are acceptable. Large bubbles
In combat emergency if Evinrude/Johnson must be eliminated through continued prim-
XD100 oil is not available, you must use an
oil that meets NMMA TC-W3 certification
standards. Operating time should be limited
to the duration of the combat emergency and
the operator should return to operating on
Evinrude/Johnson
possible.
ing.
XD100
as
soon
as
IMPORTANT: Failure to follow oil specifica-
tions could void the engine warranty if a lubri-
cation-related failure occurs.
1
2
1. Large bubble
2.
Small bubbles
FILLING THE OIL TANK
Remove the engine cover to access the oil OILING SYSTEM OPERATION
tank. Remove the filler cap and fill the tank
with the recommended outboard lubricant.
The oil tank capacity is 2.0 quarts (1.9 liters)
Break-In
New outboards are programmed to use addi-
tional oil during the first two hours of operation
above 2000 RPM. No other action is required
by the operator.
IMPORTANT: DO NOT add oil in the fuel
tank.
NO OIL Warning System
When the level in the oil tank falls below one-
quarter:
•
The EMM interrupts the ignition once per 50
engine revolutions to signal the operator.
The EMM then calculates remaining oil level
based on oil pump pulse cycles. When it de-
termines the oil has been used, the EMM:
Replace the filler cap and tighten securely.
Reinstall the engine cover.
•
Limits engine speed to 2500 RPM.
PRIMING THE OIL SYSTEM
To recover from NO OIL mode, stop the out-
board and add oil to tank. The warning resets
after the pump cycles for a minimum of three
pulses with the oil level above one-quarter.
The oiling system must be primed before us-
ing the outboard if:
•
•
•
The outboard is new;
You run completely out of oil; or
The outboard is laid down for transportation
or storage.
15
Categories | BRP Brand Manuals, Evinrude Brand Manuals, Evinrude MFE Manual, Evinrude Outboard Manual |
---|---|
Tags | Evinrude 55 hp, Evinrude MJRL, Evinrude MRL |
Model Year | 2011 |
Download File |
|
Document File Type | |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)