Chapter 6: Plumbing
Seawater Systems
Seacocks
!
CAUTION
SYSTEM DAMAGE HAZARD!
Before using a seawater intake system, make sure that the system’s seacock is in the Open
position before the system is started and keep the seacock Open until the system is shut Off.
Close the seacocks whenever the systems will not be used for long periods of time.
A seacock is a valve, controlled by a 90º lever, used to manage
the intake of seawater through the hull and below the water
line. Seacocks are typically used on your yacht in the following
seawater intake systems:
SEAWATER INTAKE VALVE (SEACOCK)
COMPONENTS (TYPICAL)
9
0 DEGREE
SEACOCK
LEVER
SEACOCK (TYPICAL)
SEACOCK GASKET
Engines
Generator (if equipped)
Air conditioning system (if equipped)
HULL
SECTION
INTAKE STRAINER
Before using any of these systems, make sure that the system’s
seacock is Open and remains Open until the system is shut Off.
Seawater Strainers
Seawater strainers are used in water pickup systems to filter incoming seawater.
A seawater strainer is located near each system’s seacock.
Check the strainers for leaks and/or debris every time you use your yacht.
If debris is found, clean the seawater strainer as follows:
!
CAUTION
FLOODING HAZARD!
The seacock that sends seawater to the strainer must be Closed before disassembling the sea-
water strainer to prevent the yacht from taking on water through the seawater
strainer assembly.
Keep the seacock Closed until the seawater strainer is completely reassembled.
SYSTEM DAMAGE HAZARD!
After reassembling the seawater strainer, make sure that the seacock valve is Open before
using the component/system.
1.
2.
Make sure the component/system (generator, air conditioning system, etc.) that the strainer is connected to is
turned Off.
Close the seacock that sends seawater to the strainer you are about to clean. The seacock must remain closed
until the strainer is completely reassembled.
3.
4.
5.
6.
7.
Take apart the seawater strainer.
Remove the debris.
Flush the strainer with water.
Reassemble the seawater strainer.
Open the seacock and check for leaks around the strainer. If no leaks are found, you may use the component
or system.
37
Product Specification
CategoriesMaxum Manuals
Tags
Model Year2009
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 80 pages
Document File TypePDF
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website