2009 Maxum 2700 SE Sport Cruiser Supplement Guide

Chapter 6: Plumbing
Autofloat Switches
The autofloat switches turn the bilge pumps On when water rises above a preset level.
Test each autofloat switch often.
Autofloat switch testing:
AUTOFLOAT SWITCH
TESTING
1.
Lift the autofloat switch test but-
ton to turn On the bilge pump.
If the pump does not turn On, check
the push-to-reset circuit breaker.
TEST BUTTON
If the circuit breaker is good, but
the switch still does not work, it
may mean the switch is bad, or the
battery is dead.
2.
After testing, push the test button
all the way down to reset auto
mode.
LIFT TEST BUTTON UP
PUSH TEST BUTTON DOWN
(BILGE PUMP SHOULD TURN ON)
(BILGE PUMP SHOULD TURN OFF)
!
CAUTION
When the test is completed on each float switch, you MUST push the test button ALL THE
WAY DOWN to reset auto mode!
46
Product Specification
CategoriesMaxum Manuals
Tags
Model Year2009
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 108 pages
Document File TypePDF
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website