LUBRICATION
Gearcase
Steering System
The installer was instructed to grease the steering
cable ram during installation. Periodic regreasing of
the steering cable ram with Triple-Guard grease is
Replace gearcase lubricant after first 10 hours of       required.  Refer  to  Engine  Maintenance  and  In-
operation. Check level and condition of lubricant af-
ter next 50 hours of operation. Add lubricant if nec-
essary.
spection Schedule for lubrication frequency. Refer
to   steering   system   manufacturer’s   information
when servicing boat’s steering system.
Thereafter, check level and condition of lubricant
every 50 hours. Replace lubricant every 100 hours
of operation or once each season, whichever oc-
curs first. Refill with Ultra-HPF gearcase lubricant.
If not available, Hi-Vis®  or other marine  gearcase
lube  can  be  used,  however,  long  term  durability
may be affected with continued use. See your Deal-
er.
IMPORTANT:  The recommended  gear  lubricants
include  special  additives  for  marine  applications.
Do not use automotive gear lubricants, 2-stroke or
4-stroke
engine oil, or any other oil or grease for
gearcase applications.
With motor in normal operating position:
Remove drain/fill plug and lubricant level plug from
side of gearcase and completely drain gearcase of
old lubricant.
Examine  drained  lubricant  for  metal  filings,  milky
appearance, or black color with burnt odor. If old lu-
bricant has any of those characteristics, see your
Dealer.  If  drained  lubricant  is  in  good  condition,
continue.
WARNING
Failure to regrease as recommended could
result in steering system corrosion. Corro-
sion can affect steering effort, making oper-
ator control difficult.
Place tube of lubricant in drain/fill hole and fill slowly
until lubricant appears at lubricant level hole. See
Engine Specifications for gearcase capacity.
Power Trim and Tilt Fluid Reservoir
Install  lubricant  level  plug  before  removing  tube
from  drain/fill hole. Drain/fill plug   can  then  be  in-   Tilt the motor up and engage the tilt support. De-
stalled without loss of lubricant.
Securely tighten both plugs.
pending on your model, refer to Tilting    or Power
Trim and Tilt. Remove filler cap and check fluid
level. If necessary, add enough Evinrude/Johnson
Power Trim/Tilt  and Power Steering  Fluid to bring
the fluid level even with the bottom of the fill cap
hole when the unit is at full tilt.
1.
2.
Drain/fill plug
Lubricant level plug
IMPORTANT:  Correct  fluid  level  must  be  main-
tained to ensure operation of the impact protection
built into this unit.
Maintenance - 43
Product Specification
CategoriesBRP Brand Manuals, Evinrude Brand Manuals, Evinrude Outboard Manual
Tags, , , , , , , , ,
Model Year2006
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 62 pages
Document File TypePDF
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

One thought on “2006 Evinrude 115 135 150 175 hp Direct Injection FPL FSL FPX FCX FHL Outboard Owners Manual

  1. necesitaria el manual del motor etc evinrude 115 hp año 2012 en castellano

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website