FAULT TRACING SCHEME
TRACING FAULTS WITH INTERRUPTIONS IN OPERATION
The fault tracing scheme given below lists only the most usual reasons for faults that give
rise to interruptions in operation. With the help of the instructions given in this handbook,
the owner can generally remedy most of the reasons for the faults listed below. When in
doubt always contact the nearest Volvo Penta service shop.
Reason
See
Main switch not switched on; flat pp 5, 12, 16,
battery, breakage in electric
cables or blown fuse.
17, 27
X
X
Empty fuel tank, closed fuel
cock, blocked fuel filter
pp 17, 18
pp 17, 18, 19
X
Water, air or impurities in fuel
Defective injector
X
X
X
X
X
X
X
pp 18, 26
p 25
Idling speed not properly
adjusted
X
X
Boat overloaded
X
X
Marine growth on boat bottom
Damaged propellor
X
Blockage in cooling water
intake, cooling jackets, defective
impeller, or thermostat
p 15
X
24
Categories | Volvo Penta Manuals |
---|---|