2009 Maxum 2400 SC3 Sport Boat Owners Manual Guide

Chapter 6: Plumbing
Autofloat Switch
The autofloat switch turns the bilge pump On when water rises above a preset level.
Test the autofloat switch often.
Autofloat switch testing:
AUTOFLOAT SWITCH
TESTING
1.
Lift the float switch test button to
turn On the bilge pump.
If the pump does not turn On, check
the fuse on the fuse block.
TEST BUTTON
If the fuse is good, but the switch
still does not work, it may mean the
switch is bad, or the battery is dead.
2.
After testing, push the test button
all the way down to return the float
switch to auto mode.
LIFT SWITCH UP
PUSH SWITCH DOWN
(BILGE PUMP SHOULD TURN ON)
(BILGE PUMP SHOULD TURN OFF)
!
CAUTION
When the test is completed on the float switch, you MUST push the test button ALL THE WAY
DOWN to return the switch to auto mode!
30