do not attempt to flush toilet again until vacuum
pump.stops.running..A.small.amount.of.water.
should remain in the bowl after flushing.
P-Trap Air Vent
Waste
Deck Fill
3..
Do.not.dispose.of.sanitary.napkins.or.other.non-
dissolving.items.in.toilet,.such.as.facial.tissue.or.
paper.towels..These.items.can.cause.plugging.of.
the.system..Refer.to.the.“Deodorants.and.Special.
Tissue” section in the manufacturer’s manual for
more.information.
Macerator Pump
Single Wye
Sealand Filter
2.
Flush For
3. Do Not
1.
Add Water
3
Seconds
Seacock
Lift
Press
Figure J-6: Overboard Discharge Option -
(Representative View Only - Description & Location may vary
depending on model).
Figure J4: VacuFlush Operations
P-Trap Air Vent
Waste
Deck Fill
NOTICE
The macerator pump must be used to
discharge waste overboard. However, DO
NOT use the macerator pump to discharge
waste at a pumping station.
Sealand Filter
Vacuum
Generator
To.operate.the.overboard.discharge.system:
1..
The.discharge.valve.is.located.in.the.engine.
compartment.labeled.HEAD.DISCHARGE..To.
open,.turn.the.valve.so.that.the.handle.is.parallel.
to the flow of the valve. The waste deck plate
cover.must.be.tightened.securely.for.the.over-
board.discharge.system.to.operate.
Figure J-5: VacuFlush® Vacuum Generator and Waste
Deck Fill - (Representative View Only - Location may
vary depending on model).
2.. Turn.ON.the.macerator.pump.switch.which..
is.located.in.the.head.on.the.switch.panel..Allow.
the.pump.to.run.until.the.storage.tank.is.empty..
The.sound.of.the.pump’s.motor.load.and.speed.
will.change.when.the.tank.becomes.empty.
B. Head With Overboard Discharge
This.option.is.available.on.most.Vista .models..The.
®
head.toilet.operations.are.the.same.as.the.systems.
described earlier but an additional line with a “Y” has
been.installed.for.overboard.discharge..The.waste.will.
be.pumped.into.the.holding.tank.from.the.head..The.
macerator pump is installed after the “wye”. Refer to
Figures.J-5.&.J-6...
3.. Turn.the.switch.off.
4.. Turn.the.discharge.valve.handle.to.the.closed.
position,.and.secure.it..The.thru-hull.valve.must..
be.closed.to.prevent.water.from.being.forced..
back.into.the.system.
Water and Waste Systems - Section J
Owner’s Manual Page 0
Categories | Four Winns Manuals, Four Winns Vista Manuals, Outboard Marine Corporation Manuals |
---|---|
Tags | Four Winns Vista 348 |
Model Year | 2005, 2006 |
Download File |
|
Document Type | Owner's Manual |
Language | English |
Product Brand | Boats and Cruisers, Four Winns. For support contact your dealer at http://www.fourwinns.com/locate-dealer.aspx |
Document File Type | |
Publisher | fourwinns.com |
Wikipedia's Page | Outboard Marine Corporation |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)