do not attempt to flush toilet again until vacuum
pump.stops.running..A.small.amount.of.water.
should remain in the bowl after flushing.
P-Trap Air Vent
Waste
Deck Fill
3..
Do.not.dispose.of.sanitary.napkins.or.other.non-
dissolving.items.in.toilet,.such.as.facial.tissue.or.
paper.towels..These.items.can.cause.plugging.of.
the.system..Refer.to.the.“Deodorants.and.Special.
Tissue” section in the manufacturer’s manual for
more.information.
Macerator Pump
Single Wye
Sealand Filter
2.
Flush For
3.  Do Not
1.
Add Water
3
Seconds
Seacock
Lift
Press
Figure J-6: Overboard Discharge Option -
(Representative View Only - Description & Location may vary
depending on model).
Figure J4:  VacuFlush Operations
P-Trap Air Vent
Waste
Deck Fill
NOTICE
The macerator pump must be used to
discharge waste overboard. However, DO
NOT use the macerator pump to discharge
waste at a pumping station.
Sealand Filter
Vacuum
Generator
To.operate.the.overboard.discharge.system:
1..
The.discharge.valve.is.located.in.the.engine.
compartment.labeled.HEAD.DISCHARGE..To.
open,.turn.the.valve.so.that.the.handle.is.parallel.
to the flow of the valve. The waste deck plate
cover.must.be.tightened.securely.for.the.over-
board.discharge.system.to.operate.
Figure J-5:  VacuFlush® Vacuum Generator and Waste
Deck Fill - (Representative View Only - Location may
vary depending on model).
2..  Turn.ON.the.macerator.pump.switch.which..
is.located.in.the.head.on.the.switch.panel..Allow.
the.pump.to.run.until.the.storage.tank.is.empty..
The.sound.of.the.pump’s.motor.load.and.speed.
will.change.when.the.tank.becomes.empty.
B.   Head With Overboard Discharge
This.option.is.available.on.most.Vista .models..The.
®
head.toilet.operations.are.the.same.as.the.systems.
described earlier but an additional line with a “Y” has
been.installed.for.overboard.discharge..The.waste.will.
be.pumped.into.the.holding.tank.from.the.head..The.
macerator pump is installed after the “wye”. Refer to
Figures.J-5.&.J-6...
3..  Turn.the.switch.off.
4..  Turn.the.discharge.valve.handle.to.the.closed.
position,.and.secure.it..The.thru-hull.valve.must..
be.closed.to.prevent.water.from.being.forced..
back.into.the.system.
Water and Waste Systems - Section J
Owner’s Manual Page 0
Product Specification
CategoriesFour Winns Manuals, Four Winns Vista Manuals, Outboard Marine Corporation Manuals
Tags
Model Year2005, 2006
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 255 pages
Document TypeOwner's Manual
LanguageEnglish
Product BrandBoats and Cruisers, Four Winns. For support contact your dealer at http://www.fourwinns.com/locate-dealer.aspx
Document File TypePDF
Publisherfourwinns.com
Wikipedia's PageOutboard Marine Corporation
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website