3)
4)
5)
Place the remote control lever in NEUTRAL
with the propeller removed.
Start the water — keep pressure between 20
to 40 psi (140 to 300 kPa).
Start the engine — run it at idle only and
flush it for at least five minutes. Check the
water pump indicator. A steady stream of wa-
ter must flow. If it does not, shut OFF the en-
gine and investigate. Refer to Engine
Overheating.
4)
If needed, use a hose connector matched to
the flushing port thread. The flushing port
thread is 0.75 – 11.5 NHR (ANSI). A suitable
connector is commercially available at most
hardware outlets.
1
6)
7)
Shut OFF the engine and remove the flusher.
Leave the outboard in vertical position long
enough to completely drain the powerhead.
Outboard — Not Running
1)
Place the engine in a tilted or vertical posi-
tion.
2
2)
Remove the plug from the flushing port.
1.
2.
Flushing port thread
Garden hose
5)
Start the water and flush the engine for at
least five minutes — keep pressure between
20 and 40 psi (140 and 300 kPa).
6)
7)
Remove the flusher (if used). Install the plug.
Lower the outboard to vertical position long
enough to completely drain the powerhead.
1
1.
Flushing port
3)
Install flushing device (if needed) and garden
hose.
Operation - 29
Categories | BRP Brand Manuals, Johnson 4-Stroke Manuals, Johnson Brand Manuals, Johnson Outboard Manuals |
---|---|
Document Type | Boat Motor Manual. Marine Operator's Engine Guide. |
Tags | Johnson 200 hp, Johnson 225 hp, Johnson CX4, Johnson CZ4, Johnson PX4, Johnson PZ4 |
Model Year | 2004 |
Download File |
|
Document File Type | |
Publisher | johnson.com |
Wikipedia's Page | Johnson Outboards |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)