If equipped with the pump out option, the waste can be   C.   Head With Overboard Discharge
removed from the  tank at a pumping  station.  A deck
plate fitting labeled WASTE, is provided for this purpose.  This option is available on all  Vista models.  The head
RefertoTableVIforlocationofthewastepumpoutfitting.           operates the same as in the porcelain head above but an
additional line with “wye” has been installed for overboard
B.   Porcelain Head
discharge.  The waste will  be pumped into the holding
tank from the head.    The macerator pump is installed
The porcelain head with holding tank is standard on the   after the holding tank. Refer to Figure G2.
model and is optional on the 238 and 258 models.
278
This is a manually-operated head. Waste holding tank
capacities and locations are listed in Table VII.
NOTICE
The macerator pump must be used to discharge
waste overboard.  However,  DO NOT use the
macerator pump to discharge waste at a pump-
ing station. If the hose is not air tight or connect-
ed properly, waste could spurt out or leak around
the deck fitting and into the boat.
Table  VI:   Waste Pumpout  Deck Fitting
MODEL
238
WASTE PUMPOUT LOCATION
Starboard, Mid Deck
Port, Aft Deck
258
278
Stbd, Mid Deck
Theheadobtainsseawaterfromapick-upforrinsingthe
bowl. The pick-up and strainer are located below the aft
cabinflooronthe278model   andintheenginebilgecom-
partment on the 238 and 258 models.
Table  VII:   Holding  Tank Capacities  &  Locations
MODEL
238
TANK CAPACITY
8 gal.
LOCATION
Stbd Engine Compartment
Stbd Mid Cabin Floor
Stbd Side Wall, Aft Cabin
258
14 gal.
278
25 gal.
Tooperate,
1.
2.
3.
Move the wet/dry bowl selector to WET BOWL posi-
tion.  Pump the handle up and down a few times to
add some water to the bowl.
To flush, make sure selector is in the WET BOWL
position and pump the handle until the bowl is thor-
oughly rinsed and evacuated.
Figure G2:   238  Waste  System With  Overboard Discharge
After flushing, move selector to DRY BOWL position
and pump handle until about one cup of water re-
mains in the bottom of the bowl.
To operate the overboard discharge system:
1.
Thedischargevalveislocatedintheenginecompart-
ment.  To open, turn the valve so that the handle is
parallel to the flow of the valve.
Leavewet/drybowlselectorinDRYBOWLpositionwhen
not in use.
Seetheappropriatemanufacturer’sinformationincluded
with this manual.
The waste deck plate cover must be tightened
securely for the overboard discharge system to
operate.
Vista Owners  Manual
10/93
Section G
Page5
Product Specification
CategoriesFour Winns Manuals, Four Winns Vista Manuals, Outboard Marine Corporation Manuals
Tags, ,
Model Year1994, 1995, 1996, 1997, 1998, 1999, 2000
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 128 pages
Document TypeOwner's Manual
LanguageEnglish
Product BrandBoats and Cruisers, Four Winns. For support contact your dealer at http://www.fourwinns.com/locate-dealer.aspx
Document File TypePDF
Publisherfourwinns.com
Wikipedia's PageOutboard Marine Corporation
CopyrightAttribution Non-commercial
(2 votes, average: 5 out of 5)
Marine readers have rated 1994-2000 Four Winns Vista 238 258 278 Boat Service Owners Manual 5.0 out of 5.0 based on 2 product reviews.
Submit your review (optional)
(will not be displayed)
* Required Field

1994-2000 Four Winns Vista 238 258 278 Boat Service Owners Manual SKU UPC Model
Daniel on Jan 03, 2013.



Alex Rivera on Oct 14, 2012.

Vista 27.8 1997


Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website