Maintenance
cables must be clean and properly con-
nected, or the battery will not start the
engine.
2.
Disconnect the negative cable(s) from
the negative (-) terminal. NOTICE: Al-
ways disconnect all negative (-) ca-
bles first to avoid a short circuit and
damage to the electrical system.
[ECM01940]
Connecting an accessory battery (optional)
1.
If connecting an accessory battery, con-
sult your Yamaha dealer about correct
wiring. For the fuse size, see ABYC (E-
11).
3.
4.
Disconnect the positive cable(s) and re-
move the battery from the boat.
Clean, maintain, and store the battery
according to the manufacturer’s instruc-
tions.
Single engine
3
2
1
4
6
5
7
ZMU05939
1.
Isolator lead with circuit protection
Red cable
Black cable
2.
3.
4.
5.
6.
7.
Fuse
Battery for accessories
Battery for starting
Negative connecting cable
EMU29371
Disconnecting the battery
1.
Turn off the battery cut-off switch (if
equipped) and main switch. NOTICE: If
they are left on, the electrical system
can be damaged.
[ECM01930]
68