Ventilation and Drainage Systems
K - 1    ENGINE COMPARTMENT
VENTILATION
K - 2    DAY BERTH & HEAD VENTILATION
The.Day.Berth.and.Head.compartment.are.equipped.
All.Four.Winns
®
.stern.drive.models.are.equipped.with.
with.hatches.which.can.be.placed.in.the.open.posi-
tion.for.ventilation.purposes..The.Day.Berth.window.
also.slides.opens.to.provide.ventilation..See.Figure.
K1..The.side.windows.(portlights).may.be.opened.to.
provide.additional.ventilation.for.both.the.Day.Berth.
and.Head.compartment.areas.
engine.compartment.ventilation..This.system.is.de-
signed.to.meet.or.exceed.the.requirements.(in.effect.
at.the.time.of.manufacture).of.the.U.S..Coast.Guard,.
the.National.Marine.Manufacturers.Association,.and.
the.American.Boat.and.Yacht.Council.
A.   Natural Ventilation System
This.system.includes.air.intake.and.exhaust.com-
ponents..The.exhaust.ducting.reaches.to.the.lower.
bilge.area..This.provides.adequate.air.movement.
while.underway.and.during.bilge.blower.operation.
B.   Forced Air Ventilation
All.Four.Winns .models.are.equipped.with.an.electric.
®
bilge.blower..The.bilge.blower.provides.the.ventilation.
required.prior.to.starting.the.engines.and.while.at.idle..
See.Section.H.-.Electrical.Systems.for.blower.opera-
tion.instructions.
Figure K1: Day Berth Window
Failure to properly ventilate the boat while the
engines or generator are operating may permit
carbon monoxide to accumulate inside the
accommodation (occupied) spaces. Refer to
Section E- - Engine Exhaust and Section B-
Gasoline vapors can explode resulting in injury
or death. Before starting the engine, check
the engine compartment bilge for gasoline or
vapors, and operate blower for four () min-
utes, and verify blower operation. Run blower
when vessel is operating below cruising speed.
ALWAYS operate the bilge blower while the
engines are at idle.
-
Carbon Monoxide for additional information.
NOTICE
Be sure hatches are secured while underway.
Damage to the hatches may result.
C.   Engine Ventilation System Maintenance
K -  3   HULL DRAINAGE SYSTEMS
A.   Transom Drain
Periodic.inspection.and.cleaning.of.the.ventilation.
ducts.is.necessary.to.ensure.adequate.air.circulation..
A.buildup.of.leaves,.twigs,.or.other.debris.can.se-
verely.reduce.ventilation..Be.sure.bilge.water.does.not.
accumulate.to.a.level.that.would.obstruct.the.ventila-
tion.ducts.
A.transom.drain.with.plug.is.provided.in.the.engine.
compartment.to.allow.water.drainage..When.the.boat.
is.out.of.the.water,.the.boat.and.trailer.should.be.
positioned.so.any.bilge.water.accumulation.during.dry.
storage will flow towards the transom.
Blower.operation.can.be.tested.by.placing.a.hand.over.
the.vents..DO.NOT.rely.on.the.sound.of.the.blower..
Be.sure.a.substantial.amount.of.air.is.being.exhausted.
by.the.bilge.blower..Check.the.bilge.blower.system.
often,.preferably.before.each.cruise.
Be sure the drain plug is securely in place
prior to launching the boat. Upon shipment of
the boat, the drain plug is usually taped to the
steering wheel.
Should.blower.noise.and.vibration.be.excessive,.
loosening.the.bilge.blower.mounting.screws.and.then.
tightening.evenly.usually.reduces.noise.considerably.
Ventilation & Drainage Systems - Section K
Owner’s Manual Page 
Product Specification
CategoriesFour Winns Manuals, Four Winns Vista Manuals, Outboard Marine Corporation Manuals
Tags
Model Year2007, 2008
Download File
Please Enter the Security Characters Shown Below. Letters are Case Sensitive. Your download link will appear upon completing this step.
- 172 pages
Document TypeOwner's Manual
LanguageEnglish
Product BrandBoats and Cruisers, Four Winns. For support contact your dealer at http://www.fourwinns.com/locate-dealer.aspx
Document File TypePDF
Publisherfourwinns.com
Wikipedia's PageOutboard Marine Corporation
CopyrightAttribution Non-commercial
(0 votes, average: 0 out of 5)

Submit your review (optional)
(will not be displayed)
* Required Field

Leave a Reply

Your email address will not be published. Required fields are marked *

*
*
Website