A magnetic catch is used on certain refrigerators. This B. Operation
latch must be properly adjusted to obtain adequate seal-
ing of the door when closed. Also, make sure retaining The Air Conditioning breaker must be turned on to acti-
pin is in place to secure refrigerator door.
vate the air conditioning unit. Depending upon humidity,
the air conditioner will condense 5 to 15 gallons of water
a day and this water drains into the sump pump. Make
sure the Sump Pump Breaker is in the ON position for
properdrainage.
NOTICE
Before installing a shore power battery charger,
refer to Section E on Electrical Systems and the
refrigerator owner’s manual. Damage to the
refrigeratormayoccurfromimproperinstallation.
AirconditionersutilizedinFour Winnsboatsareequipped
with reverse cycle heat. Thus, some heat effect can be
derived from the unit. The amount of heat that can be
obtained is limited by the temperature of the raw cooling
water pumped through the system. When the water tem-
I - 2
STEREOSYSTEM
Four Winns offers an AM/FM cassette stereo as stan- perature drops to 40 degrees Fahrenheit, the output is
dard equipment. Speakers are installed within the inte- about 50% of the maximum. At 36 degrees Fahrenheit,
rior cabins and exterior cockpit areas to provide good the output is very low. During cold conditions, an alter-
sound quality.
nate or supplemental heating system should be used.
Stereos include programming options. With the push of
a button, the stereo will automatically program radio sta-
tions. The strongest signals will be picked up but will not
necessarily be in order. To determine how to program,
refer to the stereo literature included with your owner’s
packet.
NOTICE
Most air conditioners utilize surface water as the
cooling medium. Prior to using the air condition-
ing, the boat must be in the water and the sea-
cock to the air conditioning water intake must
be in the open position. The air conditioning
seacock for water intake is in the engine com-
partment. Operating air conditioners without
proper cooling water will cause damage to the
air conditioning system.
Stereo with remote is optional on all Vista models. When
equipped, the remote control is mounted on the dash.
I - 3
AIRCONDITIONING
C. Maintenance
A. General
Clean the sea water strainer often. Also, clean the return
air filter screens, located behind the louvered doors and
Air conditioning is available only on the 278 Vista and grills, at least once a month.
operates on 120 volt (220 volt on 50 hertz models) AC
power. Dual dockside is required with air conditioning. Towinterize,refertothemanufacturer’sliteratureincluded
Be sure the appropriate shore power cord is connected with this manual.
or generator running whenever the air conditioning is to
be used. Also, refer to the manufacturer’s literature in-
cluded with this manual.
The air conditioning unit is located on the port side of the
aftcabin. Theseawaterpick-upandairconditioningpump
are located below the center cushion in the aft cabin.
The air conditioning controls are located on the port side
of the main cabin near the electrical panel. Air condi-
tioner vents are located throughout the cabin to provide
good air circulation. Vents are provided in the
v-berth, main cabin, and aft cabin. The vents are adjust-
able to change air flow direction and can be closed.
Vista Owners Manual
10/93
Section I
Page 2
Categories | Four Winns Manuals, Four Winns Vista Manuals, Outboard Marine Corporation Manuals |
---|---|
Tags | Four Winns Vista 238, Four Winns Vista 258, Four Winns Vista 278 |
Model Year | 2000 |
Download File |
|
Document Type | Owner's Manual |
Language | English |
Product Brand | Boats and Cruisers, Four Winns. For support contact your dealer at http://www.fourwinns.com/locate-dealer.aspx |
Document File Type | |
Publisher | fourwinns.com |
Wikipedia's Page | Outboard Marine Corporation |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)