Chapter 6: Plumbing
Checking for clogging debris:
1.
Remove the pump motor from the
housing:
PUMP
MOTOR
TAB
"O" RING
HOUSING
a. Lift the tab while rotating the
fins counter-clockwise.
b. Lift out the pump motor.
c. Clear the housing of debris.
Reinstall the pump motor:
2.
a. Make sure the "O" ring is prop-
erly seated.
b. Coat the "O" ring with a light
film of vegetable or mineral oil.
c. Align the cams on either side of
the pump motor with the slots
on the housing.
FIN
CAM (TYPICAL
OPPOSITE SIDE)
SLOT (TYPICAL
OPPOSITE SIDE)
d. Press the pump motor into the housing while twisting clockwise.
3.
Check the reinstallation by trying to twist the fins counter-clockwise without lifting the tab; the pump motor
should stay in place.
Autofloat Switches
•
•
The autofloat switches turn the bilge pumps On when water rises above a preset level.
Test each autofloat switch often.
Autofloat switch testing:
AUTOFLOAT SWITCH
TESTING
1.
Lift the autofloat switch test but-
ton to turn On the bilge pump.
•
If the pump does not turn On, check
the fuse on the fuse block.
TEST BUTTON
•
If the fuse is good, but the switch
still does not work, it may mean the
switch is bad, or the battery is dead.
2.
After testing, push the test button
all the way down to reset auto
mode.
LIFT TEST BUTTON UP
PUSH TEST BUTTON DOWN
(BILGE PUMP SHOULD TURN ON)
(BILGE PUMP SHOULD TURN OFF)
!
CAUTION
When the test is completed on each float switch, you MUST push the test button ALL THE
WAY DOWN to reset auto mode!