Maintenance
when installing the battery and discon-
nect the black battery cable first when
removing it. Otherwise, the electrical
parts can be damaged.
The electrical contacts of the battery
and cables must be clean and properly
connected, or the battery will not start
the engine.
7
4
3
5
2
q
1
6
Connect the RED lead to the POSITIVE (+)
terminal first. Then connect the BLACK lead
to the NEGATIVE (-) terminal.
ZMU01942
1. Battery for accessories
2.
3.
4.
5.
6.
7.
Battery for starting
Large black lead
Large red lead for starting battery
Negative connecting cable
Power for accessories
Small red lead for accessory battery charg-
ing (optional part)
NOTE:
If a battery selector switch is desired, consult
your YAMAHA dealer about correct wiring.
1.
Red cable
EMU29370
2
3.
. Black cable
Battery
Disconnecting the battery
Disconnect the BLACK cable from the NEG-
ATIVE (-) terminal first. Then disconnect the
Using an accessory battery (option)
RED cable from the POSITIVE (+) terminal.
Use a connecting cable between the (-) ter-
minals of the starting battery and accessory
battery. See the illustrations of the wiring
connections. This cable must be made from
EMU29390
Checking top cowling
Check the fitting of the top cowling by push-
ing it with both hands. If it is loose have it re-
paired by your Yamaha dealer.
wire equivalent to the starting battery cable.
EWM00600
WARNING
Use of smaller wire could lead to a fire.
71
Categories | Yamaha Outboard Manuals |
---|---|
Document Type | Boat Motor Manual Free Download. Marine Operator's Boating Guide. |
Tags | Yamaha LZ200, Yamaha Z200 |
Model Year | 2007 |
Download File |
|
Language | English |
Product Brand | Yamaha Motor. Yamaha Motor Corporation, USA - Support Customer Relations for US: 1-800-962-7926
Yamaha Boats: 1-800-962-7926 Yamaha Outboard Customer Relations: 1-866-894-1626 , Yamaha Outboard |
Document File Type | |
Publisher | yamaha-motor.com |
Wikipedia's Page | Yamaha Motor Company |
Copyright | Attribution Non-commercial |
(0 votes, average: 0 out of 5)