Trouble Recovery
EMU29471
Replacing fuse
If a fuse has blown, remove the electrical cov-
er, open the fuse holder and remove the fuse
with a fuse puller (if equipped). Replace it with
a spare one of the proper amperage.
EWM00630
WARNING
Be sure to use the specified fuse. An in-
correct fuse or a piece of wire could allow
excessive current flow. This could cause
electric system damage and a fire hazard.
1.
2.
3.
Electrical cover
Fuse puller
Spare fuse (5 A, 10 A, 15 A, 20 A, 30 A, 80
A)
NOTE:
Consult your Yamaha dealer if the new fuse
immediately blows again.
1.
2.
Electric throttle valve / ECM (Electronic con-
trol module) fuse (10 A)
Ignition coil / Fuel injector / Variable cam-
shaft timing / ECM (Electronic control mod-
ule) fuse (30 A)
3.
4.
5.
6.
7.
Main switch / PTT switch fuse (20 A)
Starter relay fuse (30 A)
Fuel feed pump fuse (5 A)
Fuel pump fuse (15 A)
Engine main fuse (80 A)